24/7 ONLINE · 09:00–00:00◆Hacettepe Teknokent / Ankara
+90 536 662 38 09[email protected]
DSETDoğanay Siber Emniyet
  • Services
  • Academy
  • Simulator
  • Blog
    BlogArticles · technical write-ups · guidesAnnouncementsLatest DSET news · bulletinsVideo GalleryTraining · demos · cyber security videos
  • About Us
    About UsThe DSET story · vision · teamSimulators and ToolsFree interactive calculators, simulators and diagnosis wizardsSector SolutionsFinance · Healthcare · Public Sector · E-Commerce · 7 industriesReference CasesReal DSET cases · industry outcomesIn the PressDSET in the national pressSite SearchAll content · articles · services · casesFrequently Asked QuestionsCommon questions · quick answersContactPhone · WhatsApp · address · form
  • Tracking System
    Customer LoginAccount dashboard · request trackingForensics RequestDigital evidence · examination requestData Recovery RequestDisk · RAID · recovery requestPrice CalculatorATK 2026 reference · 9 services
KAOS
TREN
DSETCustomer Panel

Sign in to your account

Request tracking, quote approval and your history in one panel.

Loading security verification...
DSET Customer Panel AES 256 GCM encrypted session
DSET AI
//Smart Building & IoT · 2026
Smart Building & IoT · Case 2026

A+ office complex IoT pentest · 480 cameras + BMS + elevators · 14 critical findings · TSE approval

A newly built A+ office complex requested an acceptance test from DSET. CCTV (ONVIF, 480 Hikvision cameras), BMS (BACnet, HVAC + elevators + access control), 1,200 IoT devices. Rule: impact on elevators/HVAC/access control is FORBIDDEN (human safety). With passive analysis DSET reported 14 critical findings + IEC 62443 SL2 recommendations, and the TSE acceptance test was passed.

Duration
10 business days of pentest · 60 days of IEC 62443
Scope
480 cameras · 1,200 IoT devices · a 47-floor complex
Customer Satisfaction
★★★★★

01 The Challenge

A cyber security acceptance test before the opening of a new A+ office complex. Hikvision DS-2CD2T47G2 firmware 2 years old (CVE-2021-36260 backdoor). BACnet/IP authentication: none (default, ASHRAE 135 insufficient). The elevator control panel had telnet open + admin/admin default. Human safety = impact forbidden.

02 DSET's Approach

01

T+0 · Device inventory

An inventory of 480 Hikvision cameras + 1,200 IoT devices. A risk map projecting 14 critical + 22 high + 38 medium findings.

02

T+1-6 days · Passive analysis

ONVIF + BACnet protocol analysis + read-only. Proof without impact for elevator safety. 14 critical findings (default credentials + firmware CVE + telnet).

03

T+10 days · Report + IEC 62443

An IEC 62443 SL2 target + ASHRAE 135 BACnet authentication. A board presentation was made to the building manager.

04

T+20 days · Remediation

A full DSET solution proposal: microsegmentation + a BMS security architecture. All cameras firmware updated + default credentials changed, elevator telnet closed.

05

T+45 days · Re-test + TSE

The DSET re-test was successful, 14 critical findings clean. A TSE "operational acceptance certificate" was obtained.

06

T+60 days · IoT-SOC

DSET IoT-SOC service (CCTV + BMS monitoring) was set up. Insurance premium 18% discount.

07

T+24 months · Continuously clean

DSET 24-month annual audit + IoT-SOC service. 24 months clean, 4 anomalies caught by the IoT-SOC; the brand value is referred to as a "secure office."

03 Results in Numbers

14 critical · 22 high
Findings
0
Human safety impact
Passed
TSE acceptance test
SL2 approved
IEC 62443 SL
18% discount
Insurance premium
4 (caught)
IoT-SOC anomalies (24 months)

04 Customer Testimonial

"

DSET's "human safety first" approach brought us back to DSET from other pentest firms. The passive analysis + lab testing method for elevator safety should be an industry standard.

Building Manager
A+ Office Complex · 47 floors
★★★★★

05 Key Takeaways

The IoT pentest "no-impact rule" is critical; physical impact on elevators/HVAC/access control is forbidden
Hikvision firmware CVEs are common; 2-year-old firmware must be changed in the procurement contract
BACnet authentication must be set up per the ASHRAE 135 standard; the default "no auth" is insufficient
IEC 62443 SL2 + a TSE acceptance test are indispensable for a new A+ office complex

06 Services Used in This Case

Cyber Security

Cognitive solutions.

Incident Simulator & Threat Heatmap

Not hours of deliberation · but minutes of interactive simulation.

Your case can end just as well.

Free assessment · detailed response within 48 hours.

Call Now Contact form

Other Cases

Automotive Manufacturing

Ransomware on 800 endpoints at an automotive supplier · full recovery in 9 days

View
Public Administration

Detection and cleanup of a 14-month APT intrusion at a metropolitan municipality

View
Finance

A 9-day Red Team engagement at one of Turkey's top 5 banks

View
DSETDoğanay Siber Emniyet

Digital Forensics · Data Recovery · Cyber Security · Information Security · Technical Examination · Expert Opinion · KVKK & GDPR Compliance · Digital Transformation Consulting · advanced training programs offered by DSET Academy.

+90 536 662 38 09[email protected]Hacettepe Teknokent · Üniversiteler Mah. 1596. Cad. 6. AR-GE Blokları C Blok No:6C Z.Kat · Beytepe · Çankaya · ANKARAOur Google Business Profile7/24 Online · 09.00 → 00.00 · Pazartesi · Pazar

Our Services

  • Digital Forensics
  • Data Recovery
  • KAOS Local Artificial Intelligence
  • Cyber Security
  • KVKK-GDPR Consultancy
  • DSET Academy
  • Incident Simulator & Threat Heatmap
  • Website Security
  • Information Security
  • Adli Bilişim Benchmark'ı

Support & Help

  • About Us
  • Press Room
  • Price Calculator
  • Frequently Asked Questions
  • Contact
  • EU AI Act Article 4 Guide
  • Sector Solutions
  • KVKK Disclosure Statement
  • GDPR · EU Data Rights
  • Privacy Policy
  • Cookie Policy
  • Terms of Service

Quick Links

  • Solutions
  • DFB Benchmark
  • Blog
  • Video Gallery
  • DSET Academy
  • Case Simulator
  • Reference Cases
  • Site Search
  • DSET AI Assistant
  • Digital Forensics Request Form
  • Data Recovery Request Form
  • Customer Login

Ecosystem

  • Hacettepe Teknokent
  • Cyber Security Cluster
  • USOM · National Cyber Incident Response
  • KVKK Authority
  • llms.txt
© 2026 dset.com.tr · Doğanay Siber Emniyet Teknolojileri · All rights reserved.
“Kalite asla tesadüf değildir...”
TREN
Home
References
Privacy
KVKK
GDPR
Cookies
Terms